  • Selectable noise or comb output
  • Stable output
  • 10 MHz to 6 GHz output
  • Conducted and radiated options
  • Compact and portable
  • Battery powered
 

Downloads for this product:

YRS 03 Product Information

Test Instrumentation Range Brochure

 

Description

The YRS 03 is a multi-mode, broadband noise and comb source that is capable of producing a continuous noise output or a comb of frequencies within the 10 MHz to 6 GHz range, with the step size being selected by the user. The noise generator enables observation of details over the full spectral range, while the comb generator allows for the reference signal output and noise floor to be viewed simultaneously, and the frequency accuracy of measurement of equipment to be checked.

The YRS03 is a compact and battery powered, allowing operation as an electrically small source, which minimises the effect of the YRS03 itself when characterising the electromagnetic environment. The YRS03 is housed in a metal enclosure so that it can be mounted in direct contact with a metal ground plane as may be required by some tests.

The YRS03 is supplied with a 50 Ω N-type output connector for direct connection to conducted measurement systems. For radiated operation, antennas can be attached to the unit’s output connector.

Three antennas, one monocone and two monopole optimised for different frequency bands, are available. The YRS03 is an ideal source for carrying out checks on Open Area Test Sites (OATS) and fully- or semi-anechoic chambers.

Features

Selectable noise or comb output •Flexibility across a range of applications
Stable output •Repeatable measurements
10 MHz to 6 GHz output •Applications across a broad frequency spectrum
Conducted and radiated options •Evaluation of both conducted and radiated systems
Compact and portable •Comparisons between sites and environments
Battery powered •No power or interconnecting cable effects on measurements

Applications

  • Investigation, characterisation and comparison of different measurement environments such as OATS, FAR or SAC.
  • Validation and verification of radiated and conducted measurement systems, such as:
    • Open Area Test Sites (OATS)
    • Fully Anechoic Rooms (FAR)
    • Semi-Anechoic Chambers (SAC)
    • Gigahertz Transverse ElectroMagnetic (GTEM) cells
  • Reference source for:
    • Daily pre-test checks as required by the accreditation authorities e.g. ISO 17025, DEF STAN 59-411
    • Long-term performance monitoring
    • Cable position investigation
    • Investigation of screened room behaviour
    • Characterisation of filter performance
    • Cable loss measurements
  • Measuring amplifier gain and bandwidth
  • Spectrum analyser/receiver pre-check
  • Inter-laboratory test programs
  • Proficiency test programs

Specifications

Noise Mode

Frequency range •10 MHz to 6 GHz direct connection into 50 Ω system
  •30 MHz to 6 GHz radiated using MON03 monopole and MCN03 monocone antennas
Temperature stability •<+/-1 dB, at an ambient temperature of 15 °C to 30 °C
  •<+/-1.5 dB, at an ambient temperature of 5 °C to 40 °C
Time stability •<1 dB typical over a 12 month period
Operating time •6.5 hours typical with alkaline cells

Comb Mode

Frequency Range •10 MHz to 6 GHz direct connection into 50 Ω system
  •30 MHz to 1 GHz radiated using TLM02 and MON03 monopole antennas
Comb Signal Step size Selectable between:
  •5 MHz        (5 MHz, 10 MHz,… 3 GHz min.)
  •10 MHz     (10 MHz, 20 MHz,… 3 GHz min.)
  •20 MHz     (20 MHz, 40 MHz,... 6 GHz min.)
  •40 MHz     (40 MHz, 80 MHz,... 6  GHz min.)
Temperature stability Amplitude:
  •<+/-1 dB, at an ambient temperature of 15 °C to 30 °C
  •<+/-1.5 dB, at an ambient temperature of 5 °C to 40 °C
  •Frequency; <+/- 0.5 ppm from 5 °C to 40 °C
Time stability •<1 dB typical over 12 month period
  •<+/-1 ppm typical over a 12 month period
Operating time •14 hours typical with alkaline cells

Other

Output connector •50 Ω N-type socket
Dimensions •120 mm x 120 mm x 60 mm (79 mm including connector)
Weight •1 Kg (including cells)
Power supply •4 x 1.5 V cells (AA or equivalent). Alkaline or rechargeable
Indicators •Active, low battery
Controls •Rotary switch for mode selection including OFF

Standard order kits

Part number

 

Description

  

Parts included

YRS03KIT01 Standard YRS03 • YRS03 reference source
  reference source • MCN03 - 1 GHz to 6 GHz (optimum) monocone antenna
  kit with antenna   
      
YRS03KIT02 Enhanced YRS03 • YRS03 reference source
  reference source kit • MCN03 - 1 GHz to 6 GHz (optimum) monocone antenna
  with multiple antennas • TLM02 - 30 MHz to 300 MHz (optimum)
     270 mm long top-loaded monopole antenna
    • MON03 - 200 MHz to 1 GHz (optimum)
   <equestquote-button.png" alt=E 270mm long monopole antenna
      
YRS Combination Kit Enhanced YRS02 and • YRS02 reference source
  YRS03 reference source • YRS03 reference source
  kit with multiple antennas • TLM02 - 30 MHz to 300 MHz (optimum)
  and LISN adapter with output  270 mm long top-loaded monopole antenna
  range from 5 kHz to 6 GHz • MON03 - 200 MHz to 1 GHz (optimum)
     270mm long monopole antenna
    • MCN03 - 1 GHz to 6 GHz (optimum) monocone antenna
    • LSA03 - LISN adapter with IEC 320 style connector
    • CAL16 - 9kHz to 1 GHz output measured using a
     spectrum analyser, all modes (YRS02 only)

All kits are supplied with:

Alkaline batteries; hard case; manual; CAL19 – 30 MHz to 6 GHz output power measurements in all modes using a spectrum analyser or receiver.

Accessories

TLM01  200 MHz to 1 GHz (optimum) 100 mm top-loaded monopole
TLM02 30 MHz to 300 MHz (optimum) 270 mm long top-loaded monopole
MON03 200 MHz to 1 GHz (optimum) 270 mm long monocone
MCN03 1 GHz to 6 GHz (optimum) 120 mm diameter monocone
LSA03 LISN adapter with IEC 320 style connector
NIA01 ISN adapter with RJ11/RJ14/RJ25/RJ45 style connection

Manufacturers Calibrations

CAL17  Radiated field strength, 30 MHz to 1 GHz, measured at 3 m OR 10 m on an OATS using a spectrum analyser or receiver. All modes.
CAL18 Radiated field strength, 30 MHz to 1 GHz, measured at 3 m in a FAR using a spectrum analyser or receiver. All modes.
CAL19 Conducted output power, 30 MHz to 6 GHz, measured using a spectrum analyser. All modes.
CAL21 Radiated field strength, 1 GHz to 6 GHz, measured at 3 m in a FAR using a spectrum analyseror receiver. Noise, 20 MHz and 40 MHz comb modes.

Typical Output Measurement Results

YRS03 graph 1 conducted Noise 1GHz
YRS03 graph 2 conducted Noise 6GHz

YRS03 graph 3 Radiated Noise MON03

YRS03 graph 4 Radiated Noise MCN03

YRS03 graph 5 conducted 5MHz comb

YRS03 graph 6 conducted 10MHz comb

YRS03 graph 7 conducted 20MHz comb

YRS03 graph 8 conducted 40MHz comb

YRS03 graph 9 Radiated 10M comb MON03

YRS03 graph 10 Radiated 40M comb MON03

YRS03 graph 11 Radiated 20M comb MCN03

YRS03 graph 12 Radiated 40M comb MCN03

ABOUT US