Tel: +44 (0) 1904 324440

CGE01

Comb Generator Emitter 01


CGE01KIT06

Image shown is of a CGE01KIT06

distributor-button

requestquote-button

 

  • Stable Output
  • Conducted and radiated options
  • 50 MHz to 18 GHz output
  • 50 MHz step size
  • Compact and Portable
 

Downloads for this product:

CGE01 Product Information

Test Instrumentation Range Brochure

Comb Generator Emitter 01

Description

The Comb Generator Emitter 01 (CGE 01) is a compact, battery-powered, reference signal source that generates a broadband radiated and/or conducted output up to 18 GHz. When used as a verification reference source, the known output allows unknowns within systems or components to be measured or calculated. The compact size allows small enclosures to be evaluated when used as a reference source for shielding effectiveness measurements.

The CGE 01 can be supplied with a 50 Ω SMA output connector (CGE01C) for direct connection to conducted test systems, or to an external antenna in order to generate test fields for evaluating radiated emission test systems. Alternatively, to achieve the best repeatability and compactness for purely radiated applications, the CGE 01 can be supplied with an integrated antenna (CGE01R).

The CGE01 harmonic steps can be switched between 80 MHz and 100 MHz as standard, allowing more frequency points to be measured than is possible with a fixed-frequency source. A 50 MHz/80 MHz step option is available by special request, allowing measurements compliant with chamber validations above 1 GHz according to CISPR 16.

Features:

Stable Output •  Repeatable measurements
Conducted and radiated options •  Evaluation of both conducted and radiated systems
50 MHz to 18 GHz output •  Applications across a broad frequency spectrum
50 MHz step size •  Complies with CISPR 16 validation methods
Compact and Portable •  Comparisons between sites and environments
  •  Shielding effectiveness measurements even of small enclosures
Battery powered •  No power or interconnecting cables affecting measurements

Applications:

  • CISPR 16 verifications
  • Shielding effectiveness of small enclosures e.g. PCs, servers, wireless communications equipment
  • Radiated measurement systems validation and verification
  • Reference source for:
    • Daily pre-test verification checks if required by the accreditation authorities
    • Long-term performance monitoring
    • Spectrum analyser / receiver pre-checks
  • Investigation of reverberation (mode stirred) chamber behaviour
  • Characterisation of filter performance
  • Cable loss measurements
  • Inter-laboratory test programs
  • Proficiency test programs

Specifications

Frequency Range50 MHz to 18 GHz direct connection into a 50 Ω system
 1 GHz to 18 GHz radiated using the integral antenna (CGE01R)
  or additional monocone antenna (CGE01C)
Step Size80 MHz or 100 MHz switchable
  (50 MHz or 80 MHz switchable version available to special order)
Output connector50 Ω SMA socket (CGE01C only)
Temperature Stability    1 to 16 GHz: <0.5 dB, or
  100 MHz to 18 GHz: <2 dB, at an ambient temperature of 15 °C to 35 °C
Time stabilityTypically <1 dB over a 12 month period
DimensionCGE01C with battery pack - 76 mm diameter × 64 mm (74 mm incl. connector)
 CGE01C without battery pack - 76 mm diameter × 18 mm (28 mm incl. connector)
 CGE01R with battery pack - 76 mm diameter × 92 mm
 CGE01R without battery pack - 76 mm diameter × 46 mm
WeightApprox 550g (including battery)
Power supply5 V 2 AHr battery pack. External input 4.75 V to 7.5  V, 300 mA
Operating Time6.5 hours typical with a fully charged battery pack
IndicatorsMode 1; 80 MHz steps. Mode 2; 50 MHz or 100MHz steps

 

Standard Kits:  80MHz & 100MHz switchable comb step size

Part Number

Description

 

Parts included

CGE01KIT01Standard CGE01C comb generatorCGE01C comb generator emitter with SMA
 emitter (conducted output) kit output connector
  CAL13 - conducted output power
   measurement, 0 GHz to 18 GHz
    
CGE01KIT02Standard CGE01R comb generatorCGE01R comb generator emitter with
 emitter (radiated output) kit integral antenna
  CAL09 - radiated electric field strength
   measurement, at 3m in a FAR, 1 GHz to 18 GHz
    
CGE01KIT03Enhanced CGE01C comb generatorCGE01C comb generator emitter with SMA
 emitter (conducted and radiated output) kit output connector
  MCN02 - detachable monocone antenna
  CAL13 - Standard conducted output
   power measurement, 0 GHz to18 GHz
    

Special order kits: 50MHz & 80MHz switchable comb step size

Part Number

Description

Parts included

CGE01KIT04CGE01C comb generator emitterCGE01C comb generator emitter with SMA
 (conducted output) kit output connector
  CAL13 - conducted output
   power measurement, 0 GHz to 18 GHz
    
CGE01KIT05CGE01R comb generator emitterCGE01R comb generator emitter with
 (radiated output) kit integral antenna
  CAL09 - radiated electric field strength
   measurement, at 3 m in a FAR, 1 GHz to 18 GHz
    
CGE01KIT06Enhanced, CGE01C comb generatorCGE01C comb generator emitter with SMA
 emitter (conducted and radiated output) kit output connector
  MCN02 - detachable monocone antenna
  CAL13 - conducted output power
   measurement, 0 GHz to 18 GHz

All kits are supplied with:

BP01 5 V 2 AHr rechargeable battery pack, BCH04 universal input battery charger, hard case, manual.

Accessories

  
MCN02Detachable monocone antenna (1 GHz to 18 GHz optimum when used with a CGE01C)
BP015 V 2AHr detachable battery pack

 

Manufacturer’s calibrations:

CAL13Conducted output power, 0 GHz to 18 GHz, measured using a spectrum analyser
CAL09Radiated field strength,1 GHz to 18 GHz, measured at 3 m in FAR using a spectrum analyser
 (CGE01R or CGE01C with monocone antenna only)

Typical Output Measurement Results:

 

ABOUT US

A wholly owned subsidiary of the University of York, we have been successfully delivering EMC training courses, designing and selling test instrumentation for over 20 years.

Privacy and cookie policies

CHANGE LANGUAGE

DISTRIBUTORS

CONTACT

York EMC Services Ltd
Market Square
University of York
Heslington
York
YO10 5DD

Tel: +44 (0) 1904 324440
Fax: +44 (0) 1904 324434
Email: enquiry@yorkemc.co.uk