Tel: +44 (0) 1904 324440

CCC 01

Cable Coupling Clamp 01

CCC01 Cable Coupling Clamp

The image shown is of a CCC01



  • Fixed cable routes
  • Cable injection assemblies
  • Supports a range of test cable sizes
  • 0.3 m & 0.5 m test lengths
  • Configurable injection conductor
  • Easy connection to test system

Downloads for this product:

CCC 01 Product Information

Test Instrumentation Range Brochure


The Cable Coupling Clamp (CCC01) is a reusable test jig for the purpose of measuring the shielding properties of cables. The CCC01 is designed to allow easy positioning of the test and injection feed cables in accordance with the layout described in IEC 96-1 Amendment 2 1993-06. This simplifies the process of making repeatable measurements aimed at assessing the coupling and shielding effectiveness properties of a wide range of cables.

The CCC01 design is based on the details of the “launcher” arrangement, described in IEC 96-1 Amendment 2 1993-06 section A.5.6 Line Injection Method (frequency domain). This arrangement is also used in IEC 62153-4-6: 2006 and mandated for the line injection method in EN 50289-1-6.


Fixed cable routesRepeatable layout of test and injection cables
Cable injection assembliesInjection cable runs are supplied preassembled and fitted with
  ferrite common mode chokes
Supports a range of test cable sizes2.5 mm, 5 mm and 10 mm aperture supports provided as
  standard. Cable dimensions up to 22 mm x 13 mm are possible
  with the user-machinable fitting accessories
0.3 m & 0.5 m test lengthsBase plate allows the injection assemblies to be mounted either
  for a 0.3m cable length (EN 50289-1-6) or the extended 0.5 m
  length  (IEC 96-1) for increased coupling distance
Configurable injection conductorSelf-adhesive copper tape, easily trimmed to the correct width
  required according to the circumference of the cable under test
Easy connection to test systemInjection cables are terminated in N-type connectors


  • Cable shielding effectiveness measurements as indicated by:
    • IEC 96-1 Amendment 2 1993-06
    • IEC 62153-4-6:2006
    • EN 50289-1-6
  • Investigation of cable coupling phenomena


Frequency Range10 kHz to 1 GHz typical (usable to higher frequencies, depending on the cables
   being tested and application of the test)
Output connectors50 Ω N-type sockets
Cable sizesApprox. 2.5 mm to 10 mm diameter using the three sets of fittings supplied.
 User-machinable fittings available as accessories, supporting maximum of cable
  dimension of 22 mm x 13 mm (rectangular cross-section) or a 13 mm diameter
Dimensions220 mm × 880 mm (0.5 m test setting)
 220mm × 740mm (0.3m test setting)
Weight3 kg (typical excluding cable-under-test and any associated ferrites)


Standard Kits

Part Number


Parts included

CCC01KIT01Standard CCC01 cablePair of preassembled cable injection assemblies
 coupling clamp kitBase plate with mounting positions for 0.3m and
   0.5 m cable test lengths
  2.5 mm, 5 mm and 10 mm diameter cable mounting fittings
  Additional clip-on ferrite chokes
  Self-adhesive copper tape (signal injection conductor)
  Hard case for injection assemblies and accessories
Please note: we are unable to supply the cable under test (CUT), any parts associated with its
construction and any ferrite rings to be fitted to it.


CMF01Kit of user-machinable blank fittings for custom cable apertures (single cable).
SpecialContact us for information regarding our testing service for cables to both IEC 96-1
 and EN 50289-1-6, using the CCC01.

Example Output Measurement Results



A wholly owned subsidiary of the University of York, we have been successfully delivering EMC training courses, designing and selling test instrumentation for over 20 years.

Privacy and cookie policies




York EMC Services Ltd
Market Square
University of York
YO10 5DD

Tel: +44 (0) 1904 324440
Fax: +44 (0) 1904 324434